Zhejiang aosua Refrigeration Co.,Ltd
Products
Contact Us
  • Contact Person : Mr. Steven Jaskson
  • Company Name : Zhejiang aosua Refrigeration Co.,Ltd
  • Tel : 86-575-82331987
  • Fax : 86-575-88440001
  • Address : Zhejiang,Shaoxing,Liangxiang village,Cao'e Street, Shangyu disct Shaoxing City,Zhejiang Province,China(Mainland)
  • Country/Region : China
  • Zip : 312300

Counter Flow Type Super GALUM Industrial Closed Loop Circuit Evaporative Water Cooling Tower For Induction Heating Furnace

Counter Flow Type Super GALUM Industrial Closed Loop Circuit Evaporative Water Cooling Tower For Induction Heating Furnace
Product Detailed
Related Categories:Agricultural Product Stock
Counter Flow type Super GALUM Industrial closed loop circuit evaporative water cooling tower for Induction heating furnaceDescription of AUVC closed industrial cooling towerA:Cooler system1)Copper tube:Using TP2 deacidification copper tube which the purity is 99.9%.With advantage of high anti-corrosion.Pressure-resistant design is 1.6Mpa/2)Steel tube:It is made of superior seamless steel tube which after 3 times classification and overall 2.5Mpa extreme pressures test.And it also have treatment with HDG in high temperature melting tank.So that we can make sure the steel tube have excellent performance.B:Casing1)Using mulching aluminum-zinc plate which is imported fully from South Korea.It is made of aluminum(weight ratio is 55%,volume ratio of appearance is 80%),Zinc(weight ratio is 43.3%) and silicon(weight ratio is 1.6%).The aluminum-zinc plate is composite advantage of Aluminum's anti-corrosion,heat resistance and Zinc's sacrificial anode.It becomes the best product which have composite characteristic of aluminum-plated steel plates and galvanized steel sheet.The service life is more than 3 times of common galvanized steel sheet.C:Long distance control system:1)Automatic digital display temperature control system.2)Spray pump automatic control system.3)Fan automatic control system.4)Pump control system.5)Liquid alarm system.6)High temperature alarm system.7)System failed alarm system.8)Star-delta start.9)Intelligent frequency system design.D:Fan:1)Using interior and exterior environmental fan.2)Corrosion-proof grade is IP55 and insulation class is F.3)Low noise and high transmission efficiency.E:Fan stack:Wind temptation design and conform aerodynamics.The fan stack take full advantage of gas flow field homogenization ,narrowed down the vortex flow areas and lowered flow resistance.It reduce 34% lost of air outlet kinetic energy and increase fan delivery and efficiency.F:Shield:Crimped shield can protect cooling tower from leaf,plastic bag and other things.The crimped shield effective protect the fan and safe operating of equipment.G:air-inlet grille:The air-inlet grille(PVC material) can keep off light,splash and dust.The large air output,small wind-resistance design can bring down fan energy.And there are no phenomenon that water splash out of the tower.The air-inlet grille can prevent water from sunniness that can keep using temperature and quality of spray water and avoid dusty and algal.H:Spray pump:Using high flow low head lift pump.Have advantage of low water pressure,low loss and no-blocking.I:Nozzle:Using ABS or PP material basket newest style nozzle.Have ahigh strength,long service life,fine water,uniform water spraying,large spray area and good cooling result.And it effective reducing loss of spray pump.Specifications for 6Ton closed industrial cooling towerContentStateCooling Tower Design DiameterCooling Tower TypeClosed circuit cooling towerCooling Tower ModelAFC-6Circular Water Flow30m3/hInlet/Outlet Temp37℃/32℃Environment/Wet-bulb Temp31.5℃/28℃Heat Removal Capacity30000kcal/hUsing Environment/TempOutdoor/10℃-50℃Net/Operating Weight350kg/630kgMainframeFan TypeAxial FlowFan Qty1 SetsBlowing Rate12000m3/h x1Fan Power0.75kw*1Spray Pump Power0.75kwSpray Pump Flow6.3 m³/hSpray Pump Lift12.5MMainframe L*W*H1600mm*900mm*1850mmInlet/Outlet Pipe DiameterDN50/DN50MaterialCoolerNation Standard T2 Depicted Copper Tube.Pipe Diameter:16mm;Thickness:0.6ShellUsing Super Glum  With 2mm Thickness.DewatererPVC Efficient Flow Dewaterer.RecycleSurface Moraine Of Copper PipeExhaust SystemAluminum Shell Three-Proofing Fan Motor.IP55,Insulation Level:FShieldCorrugated Shield,Avoid Fan Motor From Varia.Intake SystemAdoption Efficient Round Air Intake Grating With Sun And Splash Protection PVC.It Can Reduce Spray Water Splash And Avoid Algal.Automatic Sprinkler SystemIt Is Water Tank Spray Pump,PVC Spray Pipe,ABS New Syle Orchid Spray Header As A Whole.It Has Advantage Of Thin Water Drop,Balance And Large Area Water Distribution.Fan Control SystemHand Operation And AutoSpray Pump SystemHand Operation And AutoTemp Control SystemDigital DisplayFault Alarm SystemSound-Light AlarmIndicator LightPower On,Working And Shut DownElectrical System(Thermal Relay And a.c. Contactor Etc)Using Chint BrandColorSilveryProduction of AUVC closed industrial cooling towerWorkshop of AUVC closed industrial cooling towerShipments of AUVC closed industrial cooling towerProject case of AUVC closed industrial cooling towerPacking of AUVC closed industrial cooling towerThere are three different kinds of packing:1.Put product into iron box(when LCL transportation)2.Put product into wooden box(When LCL transportation) 3.Nude packing(when container transportation)Our services●Best Price & Good Quality for all kinds of cooling tower●We will according to your actual demand to choice the suitable cooling tower or cooling tower part to you.●We can provide Oversea technical guidance.●We can provide install video/photo or go to your country to installation guide if necessary.Payment Term:TT 30% deposit  70% balance payable within 3 days once received the copy of shipping docs(CI,PL&BL) Or L/C at sight with irrevocable


Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.